Error messages and troubleshooting
Parameter manual b maXX BM3000
Document no.: 5.12001.07
743
of 820
5
Encoder 1 Cable break - X - - IS
Cable break (SIN
2
+ COS
2
) - X - - IS
Excessive speed - X X - IS
Ramp-up option module Error during module initialization - X X - IS
Cyclical set value transmis-
sion
Time-out during transmission - X X X
5)
Safety technology Switch off by Safety technology
(Safe Torque Off)
- X - - IS
Safety technology Warning switch off by Safety tech-
nology (Safe Torque Off)
X - - - -
Blockage monitoring Drive blocked - X X - IS
Monitoring function Warning/error
Warning
Error
Adjustable threshold
Adjustable reaction
Reaction
1)
Pulse inhibit carried out after a specifiable interval
2)
Only if KTY encoder used
3)
Adjustable
4)
Not provided for power modules
IS: pulse inhibit
SH Quick stop
X: Implemented
-: Not possible