Technical data
11 Technical data
This chapter contains the technical data of the Agile series.
11.1 General technical data
CE conformity
The frequency inverters
Agile
meet the requirements of the low voltage directive
2006/95/EEC and EN 61800-5-1.
EMC directive
For compliance with standard 2004/108/EC, comply with installation instructions
in this document.
Interference im-
munity
The frequency inverters
Agile
meet the requirements of EN 61800-3 for use in
industrial environments.
UL Approval
Devices that are marked with the UL proof label fulfill the requirements according
to UL508c.
Ambient tempera-
ture
Operation: 0…55 °C; as from 40 °C power reduction should be considered.
Environmental class
Operation: 3K3 (EN60721-3-3),
maximum relative humidity 85%, no water condensation.
Degree of protec-
tion
IP20 if covers and connection terminals are used properly.
Altitude of installa-
tion
Up to 1000 m at rated specifications.
Up to 3000 m at reduced power.
Storage
Storage according to EN 50178.
BONFIGLIOLI recommends that the
unit be connected to mains voltage for 60
minutes after one year, at the latest.
Overload capacity
(o
c
)
Continuous operation 100% I
N
Up to 150% I
N
for 60 s
Up to 200% I
N
for 1 s
Overload capacity can be used every 10 minutes.
Functions
−
Control methods adjusted to motors and application (configuration)
−
Adjustable speed/torque control
−
Various protection functions for motor and frequency inverter
−
Positioning relative to a reference point
−
Flying Start function
−
S-ramps for jerk limitation during acceleration and deceleration
−
PID controller (technology controller)
−
Parameterizable Master-Slave operation via system bus
−
Error memory
−
Simplified and extended control via PC (commissioning, pa
rameterization, data
set backup, diagnosis with Scope)
−
Energy saving function
−
Automatic service messages
−
Self-learning controllers
−
Communication: System bus, CANopen®, Modbus and VABus. Profibus with
optional communication module.
Parameterization
−
Freely programmable digital inputs and outputs
−
PLC functions, can be realized via table functions or a graphical PC user inter-
face
−
Four separate data sets incl. motor parameter
−
Pre-defined motor data BONFIGLIOLI motors
277
General technical data 06/2013 Operating Instructions
Agile

Table of Contents

Other manuals for BONFIGLIOLI Agile

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BONFIGLIOLI Agile and is the answer not in the manual?

BONFIGLIOLI Agile Specifications

General IconGeneral
BrandBONFIGLIOLI
ModelAgile
CategoryDC Drives
LanguageEnglish

Related product manuals