Technical data
11 Technical data
This chapter contains the technical data of the Agile series.
11.1 General technical data
The frequency inverters
Agile
meet the requirements of the low voltage directive
2006/95/EEC and EN 61800-5-1.
For compliance with standard 2004/108/EC, comply with installation instructions
in this document.
The frequency inverters
Agile
meet the requirements of EN 61800-3 for use in
industrial environments.
Devices that are marked with the UL proof label fulfill the requirements according
to UL508c.
Operation: 0…55 °C; as from 40 °C power reduction should be considered.
Operation: 3K3 (EN60721-3-3),
maximum relative humidity 85%, no water condensation.
IP20 if covers and connection terminals are used properly.
Altitude of installa-
tion
Up to 1000 m at rated specifications.
Up to 3000 m at reduced power.
Storage according to EN 50178.
BONFIGLIOLI recommends that the
unit be connected to mains voltage for 60
minutes after one year, at the latest.
c
)
Continuous operation 100% I
N
N
for 60 s
Overload capacity can be used every 10 minutes.
Control methods adjusted to motors and application (configuration)
Adjustable speed/torque control
Various protection functions for motor and frequency inverter
Positioning relative to a reference point
Flying Start function
S-ramps for jerk limitation during acceleration and deceleration
PID controller (technology controller)
Parameterizable Master-Slave operation via system bus
Error memory
Simplified and extended control via PC (commissioning, pa
set backup, diagnosis with Scope)
Energy saving function
Automatic service messages
Self-learning controllers
Communication: System bus, CANopen®, Modbus and VABus. Profibus with
optional communication module.
Freely programmable digital inputs and outputs
PLC functions, can be realized via table functions or a graphical PC user inter-
face
Four separate data sets incl. motor parameter
Pre-defined motor data BONFIGLIOLI motors
277
General technical data 06/2013 Operating Instructions
Agile