12.9.1 Feed-through assembly (This assembly set is not included in delivery.)
The feed-through assembly facilitates the thermal separation.
The heat sink of the frequency inverter can be fed through the mounting plate. The power dissipation
can be passed on to an external cooling cycle.
12.9.1.1 Cooling air flow rate required and energy dissipation
The required cooling air flow rate and the device-specific energy dissipation P
d
of the heat sink are
listed in the following table. Additionally, the thermal radiation (energy dissipation, interior) of the
frequency inverter is indicated.
Type
Agile
202 / 402
-01
-02
-03
-05
-07
-09
-11
-13
Size 1
Cooling air
Cooling air flow rate, required m
3
/h
- - - - - - 30 30
Influencing factors
Energy dissipation, heat sink
[2 kHz]
P
d
W 12 19 29 42 53 70 89 122
Energy dissipation, interior
P
d interior
W 10 10 11 12 15 18 21 25
Type
Agile
402 -15 -18 -19 -19 -21 -22 -23
Size 2 3
Cooling air
Cooling air flow rate, required
m
3
/
h
60 60 100 100 100 100 100
Influencing factors
Energy dissipation, heat sink
[2 kHz]
P
d
W 133 167 230 235 321 393 470
Energy dissipation, interior
P
d interior
W 31 35 45 48 61 68 81
Separation of energy dissipation:
P
d interior
P
d
1
2
Energy dissipation, interior
Energy dissipation, heat sink
Mounting plate
Heat sink
P
d
P
d interior
2
1
309
Assembly variants 06/2013 Operating Instructions
Agile

Table of Contents

Other manuals for BONFIGLIOLI Agile

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BONFIGLIOLI Agile and is the answer not in the manual?

BONFIGLIOLI Agile Specifications

General IconGeneral
BrandBONFIGLIOLI
ModelAgile
CategoryDC Drives
LanguageEnglish

Related product manuals