EasyManuals Logo

BONFIGLIOLI Agile User Manual

BONFIGLIOLI Agile
360 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
Electrical Installation
5.6.1 Length of motor cables, without filter
Permissible length of motor cable without output filter
Type
Agile
202
Agile
402
unshielded cable shielded cable
Mains supply
1ph.
3ph.
3ph.
Power
kW
kW
kW
-01 1
0.09
0.18
--
50 m 25 m
-02 1
0.12
0.25
0.25
-03 1
0.18
0.37
0.37
-05 1
0.25
0.55
0.55
-07 1
0.37
0.75
0.75
-09 1
0.55
1.1
1.1
-11 1
0.75
1.5
1.5
-13 1
1.1
2.2
2.2
-15 2
1.5
3.0
3.0
100 m 50 m
-18 2
2.2
4.0
4.0
-19 2
--
--
5.5
-19 3
3.0
5.5
5.5
100 m 50 m
-21 3
3.0
7.5
7.5
-22 3
--
--
9.2
-23 3
--
--
11
The specified lengths of the motor cables must not be exceeded if no output filter is installed.