Technical data
11.2.6 AGL402 (3.0 to 11.0 kW)
Type
400 V, 3-phase
Agile
402
-15
-18
-19
-19
-21
-22
-23
Size
2
3
Output motor side
Recommended motor shaft power
P
kW
3,0
4,0
5,5
5,5
7,5
9,2
11,0
Output current
I
A
7,5
9,5
12,0
13,0
17,0
20,0
23,0
Long-term overload current (60 s)
I
A
11,2
14,2
18,0
19,5
25,5
30,0
34,5
Short-time overload current (1 s)
I
A
15,0
19,0
24,0
26,0
34,0
40,0
43,0
Switching frequency
f
kHz
2, 4, 8, 16
Output, brake resistor
Minimum brake resistor
R
Ω
106
106
106
48
48
48
48
Recommended brake resistor
(770 V)
R Ω 148
106
106 80 58 48 48
Input mains side
Rated current
I
A
6,8
7,8
13,8
14,2
15,8
20,0
26,0
Maximum mains current
1)
I
A
9,8
12,8
17,2
17,2
23,0
28,1
33,6
Fuses
I
A
10
10
16
16
25
25
35
Fuses UL type I A
Bussmann
FWP-20A14Fa
Bussmann
FWP-30A14Fa
Mechanics
Dimensions
2)
HxWxD
mm
200 x 80 x 196
200 x 125 x 205
Weight (approx.)
m
kg
1,5
3
Degree of protection
-
-
IP20 (EN60529)
Terminals A mm
2
Mains and motor ter-
minals:
0.2 … 4 (flexible with sleeve)
0.2 … 6 (rigid)
Terminals relay out-
put:
0.1 … 1.5
Installation
-
-
vertical
Interior fan
-
-
yes
Heat sink fan
-
-
yes
Ambient conditions
Power dissipation (2 kHz switch-
ing frequency)
P W 133
167
230 235 321 393 470
1) According to DIN EN 61800-5-1.
2) Dimensions of the basic device. Comply with the notes of the assembly variants in chapter 4.2
Installationfor the standard assembly and chapter 12.9Assembly variants”.
284