Technical data
11.2.3 AGL202 (3~:3.0 to 4.0 kW, 1~:1.5 to 2.2 kW, 230 V)
Type
230 V
Agile
202
-15
-18
Size
2
Output motor side
Selected Mains supply
1ph
3ph
1ph
3ph
Recommended
motor shaft power
P kW 1.5 3.0 2.2 4.0
Output current
I
A
6.0
12.0
9.0
15.0
Long-term
overload current (60 s)
I A 9.0 18.0 13.5 22.5
Short-time
overload current (1 s)
I A 12.0 24.0 18.0 30.0
Switching frequency
f
kHz
2, 4, 8, 16
Output, brake resistor
Minimum brake resistor
R
Ω
18.5
18.5
18.5
18.5
Recommended brake resistor
(385 V)
R Ω 72 37 41 27
Input mains side
Rated current
I
A
14.2
12.5
19.5
17.0
Maximum mains current
1)
I
A
20.6
18.5
28.0
25.5
Fuses
I
A
16
16
25
25
Fuses UL type
I
A
Bussmann FWP-20A14Fa
Mechanics
Dimensions
2)
HxWxD
mm
200 x 80 x 196
Weight (approx.)
m
kg
1.5
Degree of protection
-
-
IP20 (EN60529)
Terminals A mm
2
Mains and motor
terminals:
0.2 … 4 (flexible with sleeve)
0.2 … 6 (rigid)
Terminals relay out-
put:
0.1 … 1.5
Installation
-
-
vertical
Interior fan
-
-
yes
Heat sink fan
-
-
yes
Ambient conditions
Power dissipation (2 kHz
switching frequency)
P W 133 133 167 167
1) According to DIN EN 61800-5-1.
2) Dimensions of the basic device. Comply with the notes of the assembly variants in chapter 4.2
Installation” for the standard assembly and chapter 12.9Assembly variants”.
281
Device data 06/2013 Operating Instructions