3-13
Confidential
â– Error code 16
An error, which cannot be recorded, occurs while auto color registration is performed.
<User Check>
- Replace the belt unit with a new one.
â– Error code 17
Toner reaches its life end while auto color registration is performed.
<User Check>
- Replace the cartridge of toner which reaches its life end with a new one.
â– Error code 18
Auto color registration fails.
<User Check>
- Replace the belt unit with a new one.
- Replace the waste toner box with a new one.
-
-
Step Cause Remedy
1 Registration mark L PCB ASSY
failure
Replace the
registration sensor holder
ASSY
.
2 Main PCB failure Replace the main PCB ASSY.
-
-
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
-
-
Step Cause Remedy
1 Registration mark L PCB ASSY
failure
Replace the
registration sensor holder
ASSY
.
2 HVPS control PCB failure Replace the HVPS control PCB ASSY.
3 High-voltage power supply PCB
failure
Replace the high-voltage power supply
PCB ASSY.