App.1-19
Confidential
WSW15 (Redial facility setting)
- Selectors 1 through 6: Redial interval and No. of redialings
The machine redials by the number of times set by selectors 3 through 6 at intervals set by selectors
1 and 2.
- Selector 8: CRP option
If a command error occurs in the machine (calling station), the machine usually waits for three
seconds and then makes a retry three times
.
This CRP option is a request command that can be
sent from the called station for requesting the calling station to retry the failed command immediately.
WSW16 (Function setting 1)
- Selector 2: ITU-T (CCITT) superfine recommendation
If this selector is set to “1,” the machine communicates in ITU-T (CCITT) recommended superfine
mode (15.4 lines/mm). If it is set to “0,” it communicates in native superfine mode.
- Selector 7: Max. document length limitation
This selector is used to select the maximum length of a document to be sent.
- Selector 8: Stop/Exit button pressed during reception
If this selector is set to “1,” pressing the Stop/Exit button can stop the current receiving operation.
The received data will be lost.
Selector No. Function Setting and Specifications
1
2
Redial interval
No. 1 2
0 0: 5 min.
0 1: 1 min.
1 0: 2 min.
1 1: 3 min.
3
l
6
No. of redialings
No. 3 4 5 6
0 0 0 0: 16 times
0 0 0 1: 1 times
0 0 1 0: 2 times
0 0 1 1: 3 times
l
1 1 1 1: 15 times
7 Not used.
8 CRP option
0: Disable
1: Enable
Selector No. Function Setting and Specifications
1 Not used.
2
ITU-T (CCITT) superfine
recommendation
0: OFF
1: ON
3
l
6
Not used.
7 Max. document length limitation
0: 400 cm
1: 90 cm
8
Stop/Exit button pressed during
reception
0: Not functional
1: Functional