App.1-26
Confidential
â–  WSW24 (TAD setting 2)
- Selectors 3 and 4: Time length from CML ON to start of pseudo ring backtone transmission
These selectors set the length of time from CML-ON up to the start of pseudo ring backtone transmission.
In models with OGM facilities, the settings made by these selectors also apply to the length of time
from CML-ON up to the start of OGM transmission.
â–  WSW25 (TAD setting 3)
Selector No. Function Setting and Specifications
1
2
Maximum OGM recording time
(Not used.)
3
4
Time length from CML ON to start of
pseudo ring backtone transmission
No. 3 4
0 0: 4 sec.
0 1: 3 sec.
1 0: 2 sec.
1 1: 1 sec.
5
l
8
Attenuator for playback of ICM/OGM
to the line (Not used.)
Selector No. Function Setting and Specifications
1
2
External TAD no-tone detection start
delay time (Not used.)
3
4
External TAD no-tone detection level
(Not used.)
5
l
7
Pause between paging number and PIN
No. 5 6 7
0 0 0: 2 sec.
0 0 1: 4 sec.
0 1 0: 6 sec.
0 1 1: 8 sec.
1 0 0: 10 sec.
1 0 1: 12 sec.
1 1 0: 14 sec.
1 1 1: 16 sec.
8 Not used.
Note:
Selectors 5 through 7 are applicable to the USA models only.

Table of Contents

Other manuals for Brother MFC-9010CN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brother MFC-9010CN and is the answer not in the manual?

Brother MFC-9010CN Specifications

General IconGeneral
BrandBrother
ModelMFC-9010CN
CategoryAll in One Printer
LanguageEnglish

Related product manuals