Option Name Description
[2] Ctrl. ramp-down, trip This selection is similar to selection [1]
Ctrl. ramp-down, except that in [2] Ctrl.
ramp-down, trip a reset is necessary for
starting up after power-up.
[3] Coasting Centrifuges can run for an hour without
power supply. In those situations, it is
possible to select a coast function at
mains interruption, together with a flying
start, which occurs when the mains is
restored.
232 | Danfoss A/S © 2024.01 AU275649936274en-001401 / 130R0507
Programming Guide | VLT® AutomationDrive FC 360