5-56 Term. 33 High Frequency
Default value: 32000 Hz Parameter type: Range (5–32000 Hz)
Setup: All setups Conversion index: –
Data type: Uint32 Change during operation: True
Enter the high frequency corresponding to the high motor shaft speed (that is high reference value) in parameter 5-58 Term. 33 High
Ref./Feedb. Value.
5-57 Term. 33 Low Ref./Feedb. Value
Default value: 0.000 Parameter type: Range (-4999.000–4999.000)
Setup: All setups Conversion index: -3
Data type: Int32 Change during operation: True
Enter the low reference value [Hz] for the motor shaft speed. This value is also the low feedback value. See also parameter 5-52 Term. 29
Low Ref./Feedb. Value.
5-58 Term. 33 High Ref./Feedb. Value
Default value: Size related Parameter type: Range (-4999.000–4999.000)
Setup: All setups Conversion index: -3
Data type: Int32 Change during operation: True
Enter the high reference value [Hz] for the motor shaft speed. See also parameter 5-53 Term. 29 High Ref./ Feedb. Value.
5-59 Term.33 Pulse Filter Time Constant
Default value: 100 ms Parameter type: Range (1–1000 ms)
Setup: All setups Conversion index: -3
Data type: Uint16 Change during operation: False
Enter the pulse filter time constant. The pulse filter dampens oscillations of the feedback signal, an advantage when there is a lot of
noise. A high value results in better dampening but also increases the time delay through the filter.
4.6.6 5-6* Pulse Output
Use these parameters to configure pulse outputs with their functions and scaling. Terminal 27 and 29 are allocated to pulse output via
parameter 5-01 Terminal 27 Mode and parameter 5-02 Terminal 29 Mode.