l Parameter 16-13 Frequency.
l Parameter 16-14 Motor current.
l Parameter 16-16 Torque [Nm].
l Parameter 16-30 DC Link Voltage.
l Parameter 16-52 Feedback[Unit].
The following 6 parameters can be accessed from the LCP status menu in [Hand On] mode:
l Parameter 16-09 Custom Readout.
l Parameter 16-10 Power [kW].
l Parameter 16-13 Frequency.
l Parameter 16-14 Motor current.
l Parameter 16-16 Torque [Nm].
l Parameter 16-30 DC Link Voltage.
3.1.4 Main Menu
The Main Menu gives access to all parameters.
1. To enter Main Menu, press [Menu] until the indicator in the display is placed above Main Menu.
2. Use the Up/Down key to browse through the parameter groups.
3. Press [OK] to select a parameter group.
4. Use the Up/Down key to browse through the parameters in the specific group.
5. Press [OK] to select the parameter.
6. Use the Right/Up/Down key to set/change the parameter value.
7. Press [OK] to accept the value.
8. To exit, press either [Back] twice (or 3 times for array parameters) to enter Main Menu, or press [Menu] once to enter Status.
24 | Danfoss A/S © 2024.01 AU275649936274en-001401 / 130R0507
Programming Guide | VLT® AutomationDrive FC 360

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 360

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 360 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 360 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 360
CategoryDC Drives
LanguageEnglish

Related product manuals