l Parameter 16-13 Frequency.
l Parameter 16-14 Motor current.
l Parameter 16-16 Torque [Nm].
l Parameter 16-30 DC Link Voltage.
l Parameter 16-52 Feedback[Unit].
The following 6 parameters can be accessed from the LCP status menu in [Hand On] mode:
l Parameter 16-09 Custom Readout.
l Parameter 16-10 Power [kW].
l Parameter 16-13 Frequency.
l Parameter 16-14 Motor current.
l Parameter 16-16 Torque [Nm].
l Parameter 16-30 DC Link Voltage.
3.1.4 Main Menu
The Main Menu gives access to all parameters.
1. To enter Main Menu, press [Menu] until the indicator in the display is placed above Main Menu.
2. Use the Up/Down key to browse through the parameter groups.
3. Press [OK] to select a parameter group.
4. Use the Up/Down key to browse through the parameters in the specific group.
5. Press [OK] to select the parameter.
6. Use the Right/Up/Down key to set/change the parameter value.
7. Press [OK] to accept the value.
8. To exit, press either [Back] twice (or 3 times for array parameters) to enter Main Menu, or press [Menu] once to enter Status.
24 | Danfoss A/S © 2024.01 AU275649936274en-001401 / 130R0507
Programming Guide | VLT® AutomationDrive FC 360