0-21 Display Line 1.2 Small
Default value: [1614] Motor current Parameter type: Option
Setup: All setups Conversion index: –
Data type: Uint16 Change during operation: True
Select a variable to be shown in line 1, center position.
For the options of parameter 0-21 Display Line 1.2 Small, refer to parameter 0-20 Display Line 1.1 Small.
0-22 Display Line 1.3 Small
Default value: [1610] Power [kW] Parameter type: Option
Setup: All setups Conversion index: –
Data type: Uint16 Change during operation: True
Select a variable to be shown in line 1, right position.
For the options of parameter 0-22 Display Line 1.3 Small, refer to parameter 0-20 Display Line 1.1 Small.
0-23 Display Line 2 Large
Default value: [1613] Frequency Parameter type: Option
Setup: All setups Conversion index: –
Data type: Uint16 Change during operation: True
Select a variable to be shown in line 2.
For the options of parameter 0-23 Display Line 2 Large, refer to parameter 0-20 Display Line 1.1 Small.
0-24 Display Line 3 Large
Default value: [1502] kWh Counter Parameter type: Option
Setup: All setups Conversion index: –
Data type: Uint16 Change during operation: True
Select a variable to be shown in line 3.
For the options of parameter 0-24 Display Line 3 Large, refer to parameter 0-20 Display Line 1.1 Small.
4.1.5 0-3* LCP Custom Readout
Parameters for configuring the custom readout value and defining custom display texts. It is possible to customize the display elements
for various purposes.
Custom readout
The calculated value to be shown is based on settings in parameter 0-30 Custom Readout Unit, parameter 0-31 Custom Readout Min
Value (linear only), parameter 0-32 Custom Readout Max Value, parameter 4-14 Motor Speed High Limit [Hz], and actual speed.
42 | Danfoss A/S © 2024.01 AU275649936274en-001401 / 130R0507
Programming Guide | VLT® AutomationDrive FC 360