Programming Guide | VLAutomationDrive FC 360
4.23.3 34-5* Process Data
Readout of process data for motion control.
34-50 Actual Position
Default value: 0 Parameter type: Range (-1073741824–
1073741824)
Setup: All setups Conversion index: 0
Data type: Int32 Change during operation: True
The actual position in user unit.
34-56 Track Error
Default value: 0 Parameter type: Range (-2147483647–
2147483647)
Setup: All setups Conversion index: 0
Data type: Int32 Change during operation: True
Readout of the error between calculated command position and actual position in user unit.
4.24 Parameter Group 35-** Sensor Input Option
4.24.1 More Information
NOTICE
Parameter Group 35-** Sensor Input Option is only valid when VLT® Sensor Input MCB 114 is installed.
4.24.2 35-0* Temp. Input Mode
35-01 Term. X48/4 Input Type
Default value: [0] Not Connected Parameter type: Option
Setup: All setups Conversion index:
Data type: Uint8 Change during operation: True
View the temperature sensor type detected at input X48/4.
Option Name
[0] Not Connected
[1] PT100 2-wire
[3] PT1000 2-wire
[5] PT100 3-wire
[7] PT1000 3-wire
Danfoss A/S © 2024.01 AU275649936274en-001401 / 130R0507 | 293