Programming Guide | VLT® AutomationDrive FC 360
Define the limit value of delta position between adjacent sampling cycles to determine whether the target position has been reached.
This parameter works with parameter 33-45 Time in Target Window and parameter 33-47 Size of Target Window. A position is only
viewed as reached when the actual position is within the target window longer than the time set in parameter 33-45 Time in Target
Window and the delta position between adjacent sampling cycles must not be bigger than the limit value set in parameter 33-46 Limit
Value Of Delta Position In Target Window during this time.
33-47 Size of Target Window
Default value: 512 Parameter type: Range (1–65535)
Setup: 1 setup Conversion index: 0
Data type: Uint16 Change during operation: True
Define the size of the target window with user unit. This parameter works with parameter 33-45 Time in Target Window. A position is
only viewed as reached when the actual position is within this target window.
4.22.3 33-8* Global Parameters
33-83 Behavior After Error
Default value: [0] Coast Parameter type: Option
Setup: All setups Conversion index: –
Data type: Uint8 Change during operation: True
Define the action in case of an error during motion control.
Option Name
[0] Coast
[2] Controlled stop
4.23 Parameter Group 34-** Motion Control Data Readouts
4.23.1 34-0* PCD Write Par.
Parameters for readout of fieldbus data received from fieldbus master.
34-01 PCD 1 Write For Application
Default value: 0 Parameter type: Range (0–65535)
Setup: All setups Conversion index: 0
Data type: Uint16 Change during operation: True
Value received in PCD1 of fieldbus telegram.
34-02 PCD 2 Write For Application
Default value: 0 Parameter type: Range (0–65535)
Setup: All setups Conversion index: 0
Data type: Uint16 Change during operation: True
Danfoss A/S © 2024.01 AU275649936274en-001401 / 130R0507 | 289

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 360

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 360 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 360 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 360
CategoryDC Drives
LanguageEnglish

Related product manuals