Programming Guide | VLT® AutomationDrive FC 360
Data type: Uint16 Change during operation: True
View the number of drive overvoltages.
15-06 Reset kWh Counter
Default value: [0] Do not reset Parameter type: Option
Setup: 1 setup Conversion index: –
Data type: Uint8 Change during operation: True
Select to reset the kWh counter to zero.
Option Name Description
[0] Do not reset Do not reset the counter.
[1] Reset counter Press [OK] to reset the kWh counter to 0
(see parameter 15-02 kWh Counter).
15-07 Reset Running Hours Counter
Default value: [0] Do not reset Parameter type: Option
Setup: 1 setup Conversion index: –
Data type: Uint8 Change during operation: True
Select to reset the running hours counter to zero.
Option Name Description
[0] Do not reset Do not reset the counter.
[1] Reset counter Press [OK] to reset the running hours
counter to 0 (see parameter 15-01
Running Hours).
4.14.2 15-3* Alarm Log
15-30 Alarm Log: Error Code
Default value: 0 Parameter type: Range (0–255), Array [10]
Setup: 1 setup Conversion index: 0
Data type: Uint8 Change during operation: True
View the error code and look up its meaning in the chapter Troubleshooting.
15-31 InternalFaultReason
Default value: 0 Parameter type: Range (-32767–32767)
Setup: 1 setup Conversion index: 0