Programming Guide | VLT® AutomationDrive FC 360
Option Name
[141] ft/min
[160] °F
[170] psi
[171]
lb/in
2
[172] in WG
[173] ft WG
[180] HP
0-31 Custom Readout Min Value
Default value: 0.00 CustomReadoutUnit Parameter type: Range (0.00–999999.99
CustomReadoutUnit)
Setup: 1 setup Conversion index: -2
Data type: Int32 Change during operation: True
This parameter sets the minimum value of the custom readout (occurs at 0 speed). It is only possible to select a value different from 0
when selecting a linear unit in parameter 0-30 Custom Readout Unit. For quadratic and cubic units, the minimum value is 0.
0-32 Custom Readout Max Value
Default value: 100.00 CustomReadoutUnit Parameter type: Range (0.00–999999.99
CustomReadoutUnit)
Setup: 1 setup Conversion index: -2
Data type: Int32 Change during operation: True
This parameter sets the maximum value to be shown when the motor speed has reached the value set in parameter 4-14 Motor Speed
High Limit [Hz].
0-37 Display Text 1
Default value: – Parameter type: Range
Setup: 1 setup Conversion index: 0
Data type: VisStr Change during operation: True
Free text, for example, used for the device tag of fieldbus application.
0-38 Display Text 2
Default value: – Parameter type: Range
Setup: 1 setup Conversion index: 0
Data type: VisStr Change during operation: True
Free text, for example, used for the location tag of fieldbus application.