EasyManua.ls Logo

Danfoss VLT AutomationDrive FC 360

Danfoss VLT AutomationDrive FC 360
340 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Option Name Description
[0] Disabled No function.
[1] Enabled Enable the drive to catch and control a
spinning motor. When parameter 1-73
Flying Start is enabled, parameter 1-71
Start Delayand parameter 1-72 Start
Function have no function.
[2] Enabled Always Enable flying start at every start
command.
[3] Enabled Ref. Dir. Enable the drive to catch and control a
spinning motor. The search is performed
only in the reference direction.
[4] Enab. Always Ref. Dir. Enable flying start at every start
command. The search is performed only
in the reference direction.
[11] v2 Enabled Enable flying start version 2, after coast.
[12] v2 Enabled Always Enable flying start version 2, at every start.
[13] v2 Enabled Ref. Dir. Enable flying start version 2, after coast,
search in reference direction only.
[14] v2 Enab. Alw. Ref. Dir. Enable flying start version 2, ok at every
start, search in reference direction only.
1-75 Start Speed [Hz]
Default value: Size related Parameter type: Range (0.0–500.0 Hz)
Setup: All setups Conversion index: -1
Data type: Uint16 Change during operation: True
This parameter can be used for hoist applications (cone rotor). Set a motor start speed. After the start signal, the output speed leaps
to the set value. Set the start function in parameter 1-72 Start Function to [3] Start speed cw, [4] Horizontal operation, or [5] VVC+
clockwise, and set a start delay time in parameter 1-71 Start Delay.
1-76 Start Current
Default value: Size related Parameter type: Range (0.00–1000.00 A)
Setup: All setups Conversion index: -2
Data type: Uint32 Change during operation: True
Some motors, for example cone rotor motors, need extra current/starting speed to disengage the rotor. To obtain this boost, set the
required current in this parameter. Set parameter 1-72 Start Function to [3] Start speed cw or [4] Horizontal operation, and set a start
delay time in parameter 1-71 Start Delay.
1-78 Compressor Start Max Speed [Hz]
Default value: 0.0 Hz Parameter type: Range (0.0–500.0 Hz)
72 | Danfoss A/S © 2024.01 AU275649936274en-001401 / 130R0507
Programming Guide | VLAutomationDrive FC 360

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 360

Related product manuals