Option Name
[123] gal/h
[124] CFM
[125]
ft
3
/s
[126]
ft
3
/min
[127]
ft
3
/h
[130] lb/s
[131] lb/min
[132] lb/h
[140] ft/s
[141] ft/min
[145] ft
[150] lb ft
[160] °F
[170] psi
[171]
lb/in
2
[172] in WG
[173] ft WG
[180] HP
3-02 Minimum Reference
Default value: 0.000 ReferenceFeedbackUnit Parameter type: Range (-4999.000–4999.000
ReferenceFeedbackUnit)
Setup: All setups Conversion index: -3
Data type: Int32 Change during operation: True
Enter the minimum reference. The minimum reference is the lowest value obtainable by summing all references. The minimum reference
is active only when parameter 3-00 Reference Range is set to [0] Min.–Max. The minimum reference unit matches:
l The option in parameter 1-00 Configuration Mode.
l The unit selected in parameter 3-01 Reference/Feedback Unit.
3-03 Maximum Reference
Default value: Size related Parameter type: Range (-4999.000–4999.000
ReferenceFeedbackUnit)
Setup: All setups Conversion index: -3
Data type: Int32 Change during operation: True