Trip U.S
Value 36
Short description User saved parameter set has been corrupted
This trip indicates that an error has been detected in the user save parameters saved in non-volatile memory. For example, following a user save command, if the power to the drive
was removed when the user parameters were being saved.
Recommended actions:
Perform a user save in Pr mm.000 to ensure that the trip doesn't occur the next time the drive is powered up.
Ensure that the drive has enough time to complete the save before removing the power to the drive.
Trip UP.us
Value 96
Short description On board user program trip
This trip can be initiated from within an onboard user program using a function call which defines the sub-trip number.
Recommended actions:
Check the user program
Trip UPrG
Value 249
Short description User program error
An error has been detected in the onboard user program image. The sub-trip indicated the reason for the trip.