EasyManua.ls Logo

Emerson unidrive m200 - Page 81

Emerson unidrive m200
279 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
06.074 Braking IGBT Upper Threshold ±VM_DC_VOLTAGE_SET V
200V drive: 390 V
400V drive: 780 V
575V drive: 930 V
690V drive: 1120 V
RW Num RA US
06.075 Low Voltage Braking IGBT Threshold ±VM_DC_VOLTAGE_SET V 0 V RW Num RA US
06.076 Low Voltage Braking IGBT Threshold Select Off (0) or On (1) Off (0) RW Bit
06.077 Low DC Link Operation Off (0) or On (1) Off (0) RW Bit US
06.084 UTC Offset ±24.00 Hours 0.00 Hours RW Num US
06.089 DC Injection Active Off (0) or On (1) RO Bit ND NC PT US
RW Read / Write RO Read-only Bit Bit parameter Txt Text string Date Date parameter Time Time parameter
Chr Character parameter Bin Binary parameter IP IP address Mac MAC address Ver Version number SMP Slot, menu, parameter
Num Number parameter DE Destination ND
No
default value
RA Rating dependent NC Non-copyable PT Protected
FI Filtered US User save PS
Power-
down save
Unidrive M200 Parameter Reference Guide
Issue: 01.05.00.10
81

Table of Contents

Other manuals for Emerson unidrive m200

Related product manuals