MACHINE SET-UP
Page 4-24
1001 DFB
Drilling & Sawing Line
FICEP
4.4.11 Maintenance
All the checks and inspections indicated in the preceding pages must be
repeated at regular intervals (normally once every two months).
The inspection of the temperature may indicate deterioration and alteration
conditions.
Inspect the oil level as often as possible; replace the oil after 1800 to 2000
hours of operation.
Inspect the filters clogging indicators weekly and the lubrication of all
moving parts.
4.4.12 Short break of the system
No special attention is required when the system is left inoperative for a
short period of time, normally shorter than two months.
4.4.13 Long break of the system
When the system is left inoperative for a long period of time, make sure to
operate it at regular intervals, for a few minutes, to provide an adequate
lubrication to all the system components.
4.4.14 Re-start
We recommend to bleed the air after a short break.
However, if the break has been long, the system must be thoroughly cleaned
outside; before re-starting the system with the old fluid, make sure to inspect
it; replace it if it has deteriorated or altered.
In any case, check the oil level in the reservoir.