Programming and operating manual Model 1001 DFB
26 FICEP S.p.A.
That means the axes zero cycle has been correctly
performed.
Attention: to avoid wrong commands the activation of each push-button is to be performed at
least for 0.5 ÷ 1 second
Attention: Each axis has electronic barriers; their purpose is to allow a controlled and “soft”
stop of each axis. Once the axes zero cycle is executed, the electronic barriers
are activated and, if axes are manually moved, there is no risk of impact at
the end of stroke.