263
────────────────────────────────────────────────────
14.2 Type and Amount of Data That Can Be Saved
────────────────────────────────────────────────────
Format 1.2MB 1.44MB
Amount of data Approximately 23 days Approximately 28 days
Number of files 32 files 37 files
Format 1.2MB 1.44MB
Amount of data Approximately 82 days Approximately 99 days
Number of files 96 files 112 files
Format 1.2MB 1.44MB
Number of files 192 files 224 files
Data format
Item Example data Size (bytes)
Date 97/01/25 8
Time 12:34:56 8
Other than integrated power
levels
+123.45E+00 11
Integrated power levels +1234.56E+00 12
Out-of-range data +99999E+9 9
Invalid data +00000E+9 9
3. Demand Measurement mode, demand period of 30 minutes, All items set to
ON
4. Demand Measurement mode, demand period of 30 minutes, demand
measurement set to "ON", instantaneous values, power integration, average
value within a time period set to "ON"
5. Setting conditions
(3) Output format for data output to floppy disk
Measurement data is saved in text format, and the data format is shown
below. Files begin with a header section (all data that has been saved),
followed by measurement value sections listed for each time period.
A line feed is executed for the header section and for each measured value at
each time.