tion
Access Level
Select an access level for the user.
The following Web user levels, from low to high, are available:.
• Visitor—Users of this level can perform the ping and traceroute operations, but they
cannot access the device data or configure the device.
• Monitor—Users of this level can perform ping and traceroute operations and access
the data on the device, but they cannot configure the device.
• Configure—Users of this level can perform ping and traceroute operations, access
data on the device, and configure the device, but they cannot upgrade the host
software, add/delete/modify users, or back up or restore the configuration file.
• Management—Users of this level can perform any operations on the device.
Password
Set the password for the user.
Confirm Password
Enter the same password again. Otherwise, the system will prompt that the two
passwords are not consistent when you apply the configuration.
Password
Encryption
Encryption algorithm for the password:
• Reversible—The device uses a reversible encryption algorithm to encrypt the
password before saving it.
• Irreversible—The device uses an irreversible encryption algorithm to encrypt the
password before saving it.
Service Type
Set the service type, including Web, FTP, and Telnet services. This option is required.
Select at least one of the service types.
Setting the super password
Management level users can specify the password for a lower-level user to switch from the current access
level to the management level. If this password is not configured, the switchover will fail.
To set the super password:
1. Select Device > Users from the navigation tree.
2. Click the Super Password tab.
The page for setting the super password appears.