3.9 Gateway Parameter Configuration Tool
A3-169
ME0384-4A
Specifications Section
Chapter 3 Gateway Unit
[When Connecting 200V Driver Unit (RCON-SC)]
When the 200V driver unit is connected, set "Axis Number Assignment / Unit Structure Setting"
to "Automatic", and the 200V driver unit should get assigned to the last of the 24V driver units
(RCON-PC/PCF/AC/DC).
When SCON-CB is connected using the SCON extension unit (RCON-EXT), the 200V driver
unit should be assigned before SCON-CB.
Also, the 24V driver units cannot be moved or added after the 200V driver unit.