6.1 Parameter
B6-36
ME0384-4A
[Vibration Suppression No. Initial Value (Parameter No. 109)]
No. Name Unit Input range
Default initial value setting
109
Vibration suppression No.
initial value
- 0 to 3 0
A parameter dedicated to vibration damping control.
For details, refer to "6.2 Various Functions/Vibration damping control function (page B6-65)".
[Stop Method During SrvOFF (Parameter No. 110)]
No. Name Unit Input range
Default initial value setting
110
Stop method during
SrvOFF
-
0: Sudden stop
1: Decelerating stop
0
Selects Servo OFF command, drive source cutoff, and stop mode of actuator during alarm
generation (operation cancel level).
Stop command
Set value
0: Sudden stop 1: Decelerating stop
During
vibration
control
normal
positioning
During
vibration
control
positioning
control
Pausing
decelerating
decelerating
Vibration
control
decelerating
Stop
Normal
decelerating
Stop
Servo OFF
Sudden stop with emergency
stop torque
Drive-source cutoff
Alarm
(Operation cancel level)
Sudden stop with emergency stop torque
AC servo motor specification only