EasyManua.ls Logo

IAI Rcon - Page 554

IAI Rcon
838 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.1 Parameter
B6-47
ME0384-4A
Startup Section
[ABS Battery Retaining Time (Parameter No. 155)]
No. Name Unit Input range
Default initial value setting
155 ABS battery retaining time
0: 20 days
1: 15 days
2: 10 days
3: 5 days
0
This function is limited to the simple absolute specification. Set encoder positional data retention
time after turning the power supply to the actuator OFF. The setting is available in 4 levels. The
lower the motor rotation speed setting is, the longer the retention time of the positional data can
be. If there is a possibility of external force moving the workpiece conveying components of the
actuator such as the slider or rod while power is OFF, refer to the following table and calculate
motor revolution based on movement speed and set the value of this parameter faster. If the
motor revolution exceeds the set value, positional data will be lost.
The motor rotation speed can be calculated with the equation below.
Motor revolution [r/min] = Movement speed [mm/s] / Actuator lead [mm] x 60 [s/min]
For details, refer to "Startup Section Chapter 3, 3.5 Absolute Battery (page B3-12)".
Parameter
No.155
settings
Upper limit of encoder rotation speed when
power is OFF [r/min]
Battery
retaining
time
guideline
[days]
Retaining time
per 1 hour of
charge time
(guideline)
[h]
If connected actuator
is not RCA2-***NA
If connected actuator
is RCA2-***NA
0 100 75 20 6.6
1 200 150 15 5.0
2 400 300 10 3.3
3 800 600 5 1.6
24V AC servo motor specification and
stepper motor specification only

Table of Contents