6.1 Parameter
B6-53
ME0384-4A
Startup Section
Parameter list for ELECYLINDER
No.
Category
Name Unit Input range
Default setting
at shipping
Reference
Page
1 A
Operation range
adjustment
mm 0 to 9,999.69 Maximum stroke B6-54
2 A
Auto switch
"LS" signal
detection
range adjustment
mm
Actuator Depended
to 9,999.99
0.10 B6-55
3 C
Change home
return direction
- Reverse, forward
According to
ELECYLINDER
specifications
B6-56
4 B
Home position
adjustment
mm 0 to 9,999.99
According to
ELECYLINDER
specifications
B6-57
5 A
Smooth
accel/decel
setting
-
Disabled,
enabled
Disabled B6-58
6 A
Current control
setting at stop
-
Disabled,
Powerful stop
Enabled,
Energy-saving
stop
Disabled B6-59
7 A
Wireless
function setting
-
Disabled,
enabled
Enabled B6-60
8 A
Power-saving
setting
-
Disabled,
enabled
Disabled B6-60
Caution
No. 1/3/4 default factory settings differ according to ELECYLINDER specifications.
No. 7 Wireless function setting parameter is not displayed on ELECYLINDERs without
wireless circuit boards (no WL, WL2 in the Option model number).