EasyManua.ls Logo

IAI Rcon - Page 566

IAI Rcon
838 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.1 Parameter
B6-59
ME0384-4A
Startup Section
[Current control setting at stop (Parameter No. 6)]
No. Name Unit Input range
Default initial value setting
6
Current control setting at
stop
Disabled : Powerful stop
Enabled :
Energy-saving stop
Disabled
The control method for ELECYLINDER stop can be selected.
If [Disabled], a constant current value will be transmitted to the motor,
stopping it. This limits fine vibration when stopping, bringing the unit to
a complete stop.
If [Enabled], a current appropriate to the load will be transmitted to the motor,
stopping it. This limits the amount of power consumed while stopping.
If abnormal noise or vibration occurs during a gradual stop, setting to [Enabled]
may fix the issue. Moreover, setting to [Enabled] can also fix issues in which the
command position cannot quite be attained.
Caution
If [Disabled], even if a pulse deviation within ±2 from the target position remains,
movement towards the target position will not continue.
If [Enabled], if a pulse deviation of ±1 or more from the target position remains,
movement towards the target position will continue.
Elecylinder only

Table of Contents

Related product manuals