1.4 Preventive Maintenance Function
C1-8
ME0384-4A
Chapter 1 Maintenance and Inspection
Maintenance Section
[In case of EC connection unit (elecylinder)]
"Total number of movements" and "Total distance traveled" can be set and managed as the
maintenance information.
For ELECYLINDER, it is not in the parameters, but in the maintenance information screen in the
teaching tool to set the maintenance information. When each setting values are exceeded, there
should be a "maintenance warning" generated and the status LED on ELECYLINDER should
flash in green and red in turns to notify.
Even if a "maintenance warning" is generated, the ELECYLINDER will continue to operate
without interruption.
When the total travel count exceeds the set value, the user will be notified with "Maintenance
warning 1".
When "Maintenance warning 1" is output, maintenance is recommended, such as greasing.
Set the target value to a value larger than the present one and update.
Setting it to "0 times" will disable this function.
When the total travel distance exceeds the set value, the user will be notified with
"Maintenance warning 2".
When "Maintenance warning 2" is output, maintenance is recommended, such as greasing.
Set the target value to a value larger than the present one and update.
Setting it to "0m" will disable this function.
The displayed units can be switched. (m km)
All of maintenance warning LEDs from 1 to 3 on
ELECYLINDER flash in green and red in turns.
/ alternate blinking