1.4 Preventive Maintenance Function
C1-12
ME0384-4A
Chapter 1 Maintenance and Inspection
● How to Connect with PSA-24
Caution
● Use cables with cable diameter that has larger allowable current than the current volume
to be used.
There could be a concern of communication failure if using thinner cables than the
complied cable diameter. Also, make sure to use twisted pair cables for the differential
lines.
Item Specifications
diameter
AWG (UL)
AWG 22 to 20
(Copper wire)
(0.3 to 0.5 mm
2
)
Stripped length
10.0 mm
Rated Temperature of
Isolation Coating
60°C or more
* Use the following complied cables for
PSA-24 communication wiring.
Wiring should be
performed to
SD+ (Red)
SD- (White)
GND (Blue)
on the connector as shown
in figure
Wiring should be
performed to
SD+ (Red)
SD- (White)
GND (Blue)
on the connector as shown
in figure
System I/O connector