STRUCTURES / USE OF VHB TAPE FOR INSTALLATIONS AND REPAIRS 4-13
CHANGE C2 ICON A5 / MAINTENANCE MANUAL
6. Join parts using approximately 15 psi of pressure. Temperature to be between 70° F (21° C) and
100° F (38° C).
7. Allow 72 hours for 100% bond strength cure (20 minutes=50%, 60 minutes=75%, 24
hours=90%).
Installation Drawing References
ICA000500 VORTEX GENERATOR AND FENCE INSTL, FUSELAGE
• ICA009726 VORTEX GENERATOR, 2.3, INJ MLD, WHITE
• ICA009210 FENCE, FLAP ROOT, RH
• ICA009211 FENCE, FLAP ROOT, LH
ICA000501 STALL STRIP, INSTL
• ICA009265 STALL STRIP, TRIANGULAR XSECT, 18X.75
ICA000502 VORTEX GENERATOR INSTL, WING
• 05-04662 VORTEX GENERATOR, AIR WAVE
VERIFICATION METHOD:
After the tape is fully cured, pull firmly on the component to ensure that it is bonded properly to the
attaching surface.
RELATED INFORMATION:
"Wing Trailing Edge Light Fence Replacement" on page 17-16