FLIGHT CONTROLS / FLAP CONTROLS 9-75
CHANGE C3 ICON A5 / MAINTENANCE MANUAL
Line
Level of Certification
LSA-RM
Task Specific Training Required
No
Special Tools Required
None
Parts Required
MET000663-A ACTUATOR
Aircraft System and Number
06—Flight Controls
Consumables
None
1. Install replacement flap actuator by securing it to the flap actuator bracket using the retained
AN41C0A bolt. Take care to install the flap actuator in the correct orientation, with the spherical
bearing/lug between the bracket walls.
NOTE: See Figure 9-48for installation reference.
2. Connect flap actuator rod end to the flap bellcrank using the retained AN4C10A bolt and
NAS1149C0416R washer.
NOTE:See Figure 9-48 for installation reference.
3. Connect the flap actuator to the wire harness.
4. Set actuator limit switches. (See “Rigging Flap Controls” on page 9-67.)
5. Reinstall the bulkhead panel. (See “Removal and Installation of Inspection Panels and Fairings”
on page 3-34.)
VERIFICATION METHOD:
Verify actuator limit switches against Flaps Rigging. (See “Inspect Flap Rigging” on page 9-65.)