STRUCTURAL REPAIR / GENERAL BONDED FASTENER REPLACEMENT 20-5
CHANGE C0 ICON A5 / MAINTENANCE MANUAL
CHAPTER 20
use a hard plastic chisel or similar tool to wedge the adhesive off. Be careful not to damage the
underlying or surrounding substrate during this operation.
VERIFICATION METHOD:
Once all adhesive is removed, inspect the underlying substrate for damage (delaminations, blisters,
broken fibers, cracks etc.).
RELATED INFORMATION:
"General Bonded Fastener Replacement" on page 20-3
20.2.2 General Bonded Fastener Installation
Install disbonded or damaged bonded fasteners and any remaining adhesive using the procedure
below.
TASK INFORMATION:
Type of Maintenance
Line
Level of Certification
LSA-RM
Task Specific Training Required
No
Specific Tools Required
None
Parts Required
Many bonded fasteners are used in the A5. These include:
CB3000 Large Metallic Base Stud
CB3021 Reverse-Mounted Stud
CB3033 Reverse-Mounted Standoff
CB4000 Large Composite Base Stud
CB4020 Composite Right-Angle Cable Tie Mount
CB5000 Small Metallic Base Stud
CB5001 Small Base Locking Thread Standoff
CB6007 Clip-Retained Corner Nutplate
CB6009 Clip-Retained 2-Lug Nutplate
CB6010 Sealed Two Lug Nutplate
CB9120 Low Profile Cable Tie Mount
CB9205 Strap Fastener