iPECS eMG80 & eMG800 & UCP
Feature Description and Operation Manual Issue 1.6
228
Type 3 00 - 19 2 20 20 - 99 2 80
Type 4 000 - 099 3 100 1000 - 8999 4 8000
Type 5 000 - 099 3 100 100 - 999 3 900
Type 6 00 - 09 2 10 100 - 999 3 900
Type 7 00 - 09 2 10 10 - 99 2 100
Type 8 0 - 0 1 1 - 9 1 9
eMG80
Type 0 000 - 099 3 100 2000 - 4999 4 3000
Type 1 000 - 099 3 100 200 - 999 3 800
Type 2 00 - 19 2 20 200 - 999 3 800
Type 3 00 - 19 2 20 20 - 99 2 80
Type 4 000 - 099 3 100 1000 - 3999 4 3000
Type 5 000 - 099 3 100 100 - 999 3 900
Type 6 00 - 09 2 10 100 - 999 3 900
Type 7 00 - 09 2 10 10 - 99 2 90
Type 8 0 - 0 1 1 - 9 1 9
User enter the speed code to program/edit the speed dial telephone number.
Speed Dial Phone Number Programming
The speed code should be in range of selected the speed code range.
User dials Speed Dial Code to make a phone call.
SPEED Dialing
The speed code should be in range of selected the speed code range.
Conditions
1. Suggest to change Type from default before program/use SPEED Dials.
If change Type, during working with exist SPEED data, then range-out codes referred
to by preset-forward etc. will be seen as an empty or range-out-assigned(65535) that
need to be changed to a valid or need to be cleared by manual programming. If not,
features or data referring the range-out speed code will go to failure.
2. Be careful, if change speed type from 3 or more digit system-speed(xxx/xxxx/xxxxx) to
2 or less digit system-speed(x or xx) then the feature(off-net forward, etc.) data that
have 2 digit station-speed(xx) previously, may be wrong-identified as location of
system speed xx or x. And vice versa in case of change from 2 digit or less system-
speed(xx or x) to 3 or more digit speed code (xxx/xxxx/xxxxx).