Feature Description and Operation Manual Issue 1.6
130
2.41 Green Power Save for eMG
Description
The system can disable the power to LDP Phones and SLTs (Single Line Telephone) connected
to the system at pre-determined times such as at night or during holidays when no one will be
using the phones. In addition the automatic control, power to the phones can be manually
controlled from the Web Admin.
Operation
Conditions
Operation of this feature is either automatic when programmed, or by Web Admin.
1. When power is removed from an LDP Phone or SLT, the phone cannot place or
receive calls.
2. In the event of a system reset while the Green Power mode is active, after the reset,
the Green Power mode is disabled. If in the automatic mode, the Green Power mode
will reactivate when the activation time is reached.
3. Station ports 1 and 2 are not affected by the Green Power mode and these ports will
continue to operate normally to receive and place calls.
Programming
Keyset Admin.
Green mode
Green Mode Activation (PGM 500)
Green Mode Time (PGM 501)
Green Mode
Web Admin.
Green Mode Activation
Green Mode Time Setting
Related Features