iPECS eMG80 & eMG800 & UCP
Feature Description and Operation Manual Issue 1.6
405
6. ATTENDANTS
6.1 Active CPU (UCP) Display for UCP
Description
When the system is equipped for CPU Redundancy, the System Attendant can determine and
change the active and standby CPU.
System Attendant
[TRANS/PGM] + {FLEX} + [TRANS/PGM] + “078” + [HOLD/SAVE]
To assign a Flex button for Active CPU Display
1. Press the [TRANS/PGM] button.
To view the active UCP
2. Dial “078” the Active CPU Display code, the active CPU is displayed.
Or,
1. Press the {Active CPU Display} Flex button to display the active CPU.
1. Press the [TRANS/PGM] button.
To Change Standby UCP to Active UCP
2. Dial “078” the Active CPU Display code. Or, press the {Active CPU Display} Flex
button.
3. Dial “#” to change the standby iPECS UCP module to active.
Conditions
1. The system must be equipped with and properly programmed in Redundancy Data for
Redundant Processor operation and for the Attendant to display or change the active
UCP.
2. The System Attendant can assign a Flex button to indicate when the back-up iPECS
UCP module is active. When assigned, the LED of the Flex button will turn ON
indicating the back-up UCP is active.
Programming
Redundancy Attributes CPU Redundancy Usage
Related Features
Redundant System Processor
Hardware