iPECS eMG80 & eMG800 & UCP
Feature Description and Operation Manual Issue 1.6
324
4. OUTSIDE (CO/IP) LINES
4.1 Auto Fault Detection and Recovery
Description
If the system detects a Line fault on a PRI Line or SIP Trunk, the Line/Trunk is placed in an Out-
Of-Service state and temporarily placed it in the unused Line group. Upon recovery the system
will automatically return the Line to in-service. Co line fault information is provided to NMS if it is
connected.
Operation
System
Attendant
Operation of Fault Detection and Recovery is automatic.
1. Dial “*565”, the Alarm Rest code.
To terminate the alarm signal
Conditions
1. The “Unused” Line Group contains Lines that are not used or are temporally blocked.
2. This feature is only available for E1, T1 an PRI Lines, and SIP trunks.
Programming
Keyset Admin.
CO/IP
System Data
CO/IP Line Group (PGM 141-Button 1)
DCOB Fault Notify (PGM163-Button 6)
SIP Registration Fault Notify (PGM163-Button 7)
Web Admin.
Common Attributes CO/IP Group
System Data Alarm Attributes Emergency Call Notify, DCOB Fault
Notify, SIP Registration Fault Notify
Related Features
Outside Line Groups
Hardware