2.6 Auto Call Release
Description
Outside or intercom calls (except Hands-free Answerback) will be released automatically if you do
not complete dialing or, for intercom calls, the called party does not answer after a pre-
determined time.
Operation
System
1. If you place an intercom call and the called station does not answer in the Intercom Call
Release Time, the call is terminated and you will receive error tone. In addition, if the Inter-
digit Timer expires while dialing, the call is terminated and you will receive error tone.
Auto Call Release of Intercom calls
1. If you seize an idle Line and do not dial within the Automatic Release Time, the call is
terminated and you will receive error tone. In addition, if the Inter-digit Timer expires while
dialing, the call is terminated and you will receive error tone.
Auto Call Release of outside calls
Conditions
1. If the Automatic Call Release Timer is set to “0”, Auto Call Release is disabled.
2. When the handset is used to place a call, you will receive error tone for 30 seconds
followed by 30 seconds of Howler tone and the station is placed in a fault mode. If on-
hook dialing is used, you receive error tone for one (1) second and the phone returns
to idle automatically.
Programming
Keyset Admin.
Howling Tone to Station (PGM 111-Button 5)
SYSTEM CO Call Automatic Release Timer (PGM 180-Button 12)
STA Call Automatic Release Timer (PGM 182-Button 4)
Web Admin.
SYSTEM DATA System Timers Automatic CO Release Timer, Station Auto
Release Timer, Inter-digit Timer
Related Features
Howler Tone
Hardware