Feature Description and Operation Manual Issue 1.6
424
6.14 Emergency Call Attendant Alert
Description
When a station places a call to an Emergency number, the Attendant receives an emergency call
alert. The alert includes an alert tone and display of the emergency call information, which
continues until the Attendant resets the alert. The information includes the calling station number,
time and date. The system stores the most recent emergency calls (up to 16). The Attendant can
review the history at any time.
A Flex button on the Attendant phone can be used to reset the alert and terminate the alert tone.
Operation
System
Attendant
Operation of the alert is automatic.
[TRANS/PGM] + {FLEX} + “*565” + [HOLD/SAVE]
To assign a Flex button as an {ALARM RESET} button to terminate the alert
[TRANS/PGM] + {FLEX} + [TRANS/PGM] + “08” + [HOLD/SAVE]
To assign a Flex button as an {Emergency Call History} button
1. Dial the Alarm reset Code, *565, confirmation tone is received and the Alert terminates.
To terminate an alert signal while idle
Or,
Press the {ALARM RESET} button.
1. Lift the handset or press the [SPEAKER] button.
To view the Emergency Call History
2. Press the [TRANS/PGM] button.
3. Dial “08”, the Emergency Log code. The display shows the first emergency call logged in
the history.
EMERGENCY STA NO XXXX
MM/DD HH:MM (xx)
4. Press the [VOL UP] and [VOL DOWN] buttons to scroll through the call history.
5. After viewing a call history record, the record is marked as “READ” as below.
EMERGENCY STA NO XXXX
MM/DD HH:MM READ (xx)
6. If a record remains unread, the Attendant will receive alert tone upon returning to idle as
notification that a record has not been reviewed.