4.8 Digit Conversion
Description
When you place a call, the digits you dial are compared with the Digit Conversion Table. If a
match is found, the digits are converted as defined in the table. Within the table are 15 sub-tables
with up to 200 entries of up to sixteen digits for each sub-table for eMG80. With eMG800/UCP,
within the table are 32 sub-tables with up to 200 entries of up to 24 digits for each sub-table.
Different conversion can be assigned for the same dialed number based on the system service
mode and LCR configuration. Conversion can also be limited to outside calls from a station or an
outside Line. The latter may be used in networked environments where a system in the network
employs Lines from another system to place a call.
Operation
Conditions
Digit Conversion is applied automatically according to programming.
1. Each CO line can have a Digit Conversion Tables.
2. There are two (2) special entries for configuring digit conversion:
− X: Mask Digit, any digit is accepted
− F: Ignore Digit
Programming
Keyset Admin.
SYSTEM
Digit conversion Table (PGM 270)
Web Admin.
Digit Conversion Table Index
Related Features
Hardware