EasyManua.ls Logo

iPECS eMG80 - Page 285

iPECS eMG80
467 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
iPECS eMG80 & eMG800 & UCP
Feature Description and Operation Manual Issue 1.6
272
2. Dial the Network Paging code and Zone, or press a {NET PAGE ZONE} button.
3. If assigned, after the Page Warning Tone, make announcement.
4. Replace the handset to return to idle.
1. Press the[MESSAGE/CALL BACK] button.
To queue for a page when busy is received
2. Replace the handset, returning to idle.
SLT
1. Lift the handset.
To make a page
2. Dial the Network Paging code and Zone.
3. If assigned, after the Page Warning Tone, make announcement.
4. Replace the handset, to return to idle.
1. Dial “556”, the Call Back code.
To queue for a page when busy tone is received
2. Replace the handset returning to idle.
Conditions
1. The conditions such as Page Access, Page Time-out, etc. apply to Network Paging.
2. A Network Page code must be programmed in Networking Data Net Numbering Plan
in the calling system.
3. A Network Page code and page destination must be programmed in Networking Data
Net Feature Code Table in the called system.
4. The Network Page destination can be Internal Page, External Page and All Call Page.
5. You will hear error tone if there is no idle networking path or if the page destination is
invalid.
6. You can page within a networked system without lifting the handset.
Programming
Keyset Admin.
NETWORKING DATA
Net Basic Attributes
Net CO Line Attributes
Net Numbering Plan
Net Feature Code Table
NETWORKING DATA
Web Admin.
Net Basic Attributes
Net CO Line Attributes
Net Numbering Plan
Net Feature Code Table
Related Features
Internal/External & All Call Page
Hardware

Table of Contents

Other manuals for iPECS eMG80

Related product manuals