ID Index Name Unit Description
118 14 MPRO_INPUT_FILTER ms forIED03
119 0 MPRO_INPUT_STATE_FIL Statesoffilteredandinverteddigitalinputs
120 0 MPRO_INPUT_INV Digitalinputinversion:ENPO[0],ISD00..05[1..6],SH
[7],ISD06[16]
Table 9.1: “Digital standard inputs” parameters (continue)
9.2.2Functionselectors
ID Index Name / Setting Unit Description
101-107 0 MPRO_INPUT_FS_
ISDxx
Functionselectorsforthedigitalinputs
Off(0) Inputwithoutfunction
START(1) Startofcontrol:Motorisenergized.The
directionofrotationdependsonthereference.
INV(2) Inversereferencevalue
STOP(3) Carriesoutaquickstopasperthequickstop
response(active-low)
HALT(4) Disablefeed:Theongoingaxismovementis
interruptedandresumedasperthe"HALT"
reactionfollowingresetting.
LCW(5) Limitswitchpositivedirection:Limitswitch
evaluationwithoutoverrunprotection,positive
direction.Thereactiontolimitswitchoverrun
andtointerchangedlimitswitchescanbe
preset.
LCCW(6) Limitswitchnegativedirection:Limitswitch
evaluationwithoutoverrunprotection,negative
direction.Thereactiontolimitswitchoverrun
andtointerchangedlimitswitchescanbe
preset.
INCH_P(7) Joginpositivedirection
INCH_N(8) Joginnegativedirection
Table 9.2: Function selectors “Digital inputs”
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
305
9 Inputs/Outputs settings
ID Index Name / Setting Unit Description
HOMST(9) Starthomingaccordingtothehomingmethod
parameterizedinP 02261 MPRO_402_
Homing Method
HOMSW(10) Homingswitchtodeterminethezerofor
positioning
E_EXT(11) Externalerror:Errormessagesfromexternal
devicescauseanerrormessagewiththe
reactiondeterminedinparameterP 30[11] -
Reac_External
WARN(12) Externalcollectivewarning
RSERR(13) Resetalarm:Errormessagesareresetwitha
risingedgeiftheerrorisnolongerpresent.In
somespecialcaseitisnecessarytorestartthe
deviceinordertoresetanerror.Notethe
settingsinthe"Errorreactions"subjectarea
(seeSection"Errorreactions"onpage339).
MAN(14) Switchcontrollocationselector:Whenusing
fieldbusoperation,adigitalswitchcanbeused
toswitchthesetpointsourceP 165[0] -
MPRO_REF_SELandthecontrollocation
P 159[0] - MPRO_CTRL_SELto"Term".
PROBE(15) ISD00toISD04:Notdefined
ISD05andISD06:Thefunctioncanonlybe
executedviathefastinputsISD05andISD06in
conjunctionwithPLCorCANopen/EtherCAT.
PLC(16) InputcanbeevaluatedbyPLCprogram
PLC_IR(17) InterruptionofthePLCprogram
MP_UP(18) Motorpotentiometer:Increasereferencevalue
MP_DOWN(19) Motorpotentiometer:Decreasereferencevalue
HALT_PC(20) Disablefeedwithfollowingpositioncontrol
(fromV1.35-06)
TBEN(21) Importandexecutionofselectedtabledriving
set
TBTEA(22) Writeactualpositionintoselectedtableindex:
Teach-inforpositionreferences.Thecurrent
positionisstoredinthespecifiedtableindexon
arisingedge.Theindexcanbedefinedviathe
inputsinbinaryformat(setting23-26)orsetvia
P 207[0] - MPRO_TAB_ActIdx.Theteach-in