11.6.19.12Error18-12(emergencycodeFF00h)
Cause: Memoryoverflowfortablevalues
Suggested steps:
Reset error and start again
Anerroroccuredatthe
homingmethode.
l Pleaseacknowledgetheerror.
l Pleasestartthehomingmethodagain.
11.6.19.13Error18-13(emergencycodeFF00h)
Cause: Errorinitializinglastactualpositionafterrestart.
Suggested steps:
Reset error and start again
Anerroroccuredatthe
homingmethode.
l Pleaseacknowledgetheerror.
l Pleasestartthehomingmethodagain.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
380
11 Alarms & warnings
11.6.20Error19:Fatalerror
11.6.20.1Error19-1(emergencycode5400h)
Cause: PST:Dataindextoolarge
Suggested steps:
Call your service provider.
Thisisprobablyasoftware
issue.
l Pleasetrytoswitchtoadifferentversionof
devicefirmware.
l Saveyourdatasetandresettheaxismoduleto
factorysetting.Seeiftheerrorpersists,orifit
comeswithactivatingacertainfeature.
Thisispossiblyahardware
issue
Ifothermeasuresfailtosolvetheproblem,please
replacetheservocontroller.
11.6.20.2Error19-2(emergencycode5400h)
Cause: PST:Errorinswitchingfrequency-dependentdata
Suggested steps:
Call your service provider.
Thisisprobablyasoftware
issue.
l Pleasetrytoswitchtoadifferentversionof
devicefirmware.
l Saveyourdatasetandresettheaxismoduleto
factorysetting.Seeiftheerrorpersists,orifit
comeswithactivatingacertainfeature.
Thisispossiblyahardware
issue
Ifothermeasuresfailtosolvetheproblem,please
replacetheservocontroller.