11.6.55Error62:Batterybufferedencoder
11.6.55.1Error62-1(emergencycode7305h)
Cause: Encoder channel 1: Endat22, Error 'M-ALL-Power-Down' (BAT)
Suggested steps:
Multiturn position is lost! Please perform a new homing of the drive. Please reset the
encoder internal warnings and errors with parameters (642) and (644).
M-ALL-Power-Down'(BAT) l Asensorwithimplementationofthemulti-turn
partviabatterybufferisconnected.
l Theerroroccurswhenbothvoltages,onthe
onehandthenormalencodersupplyvoltage
andontheotherhandtheauxiliarybattery
voltage,hadfailedatthesametimeatthe
encoder.
l Inthiscase,themultiturnpartofthepositionis
lost.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
454
11 Alarms & warnings
11.6.55.2Error62-3(emergencycode7307h)
Cause: Encoder channel 3: Endat22, Error 'M-ALL-Power-Down' (BAT)
Suggested steps:
Multiturn position is lost! Please perform a new homing of the drive. Please reset the
encoder internal warnings and errors with parameters (642) and (644).
M-ALL-Power-Down'(BAT) l Asensorwithimplementationofthemulti-turn
partviabatterybufferisconnected.
l Theerroroccurswhenbothvoltages,onthe
onehandthenormalencodersupplyvoltage
andontheotherhandtheauxiliarybattery
voltage,hadfailedatthesametimeatthe
encoder.
l Inthiscase,themultiturnpartofthepositionis
lost.
11.6.56Error63:Errorbrakemonitoring
11.6.56.1Error63-1(emergencycode6100h)
Cause: Brake monitoring error, cannot reach target torque, brake remains closed
Suggested steps:
Check torque or system limits, control settings or motor data set
Thisispossiblyahardware
issue
Ifothermeasuresfailtosolvetheproblem,please
replacetheservocontroller.