ID Index Name Unit Description
254 0 MPRO_ECAM_Egear_
GearOutMode
EGEAR:GearOut-disengagementmode
256 0 MPRO_ECAM_Egear_
GearOutDec
rev/min/s EGEAR:GearOut-decelerationrampfor
disengagement
258 0 MPRO_ECAM_Egear_
GearOutDist
incr EGEAR:GearOut-disengagementdistance
264 0 MPRO_ECAM_Egear_
GearOutJerk
rpm/s^2 EGEAR:GearOut-accelerationrampjerkfor
disengagement
Table 8.40: “Synchronized motion - Electronic gearing - Disengagement” para-
meters
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
289
8 Motion profile
8.12VirtualMaster
Image 8.74: "Virtual master" screen
Click "Start" to start the engagement and click "Stop" and "Halt" correspondingly to
stop it.
NOTE
l Thevirtualmastermustbeactivatedbyclickingthe"Start"button,
andremainsactiveforoperationofasynchronizedmovement.