11.6.45Error49:Safetysystemerror
11.6.45.1Error49-0(emergencycode6100h)
Cause: Unknown fatal error in functional safety interface
Suggested steps:
Read additional information, check safety system or wiring and acknowledge
alarm/error
Thisisprobablyasoftware
issue.
l Pleasetrytoswitchtoadifferentversionof
devicefirmware.
l Saveyourdatasetandresettheaxismoduleto
factorysetting.Seeiftheerrorpersists,orifit
comeswithactivatingacertainfeature.
Thisispossiblyahardware
issue
Ifothermeasuresfailtosolvetheproblem,please
replacetheservocontroller.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
442
11 Alarms & warnings
11.6.45.2Error49-1(emergencycode6100h)
Cause: Alarm on safety controller SR1 of master or local device detected
Suggested steps:
Read additional information, check safety system or wiring and acknowledge
alarm/error
Extendeddiagnosisofsafety
errors/alarms.
l Furtherinformationontheerror/alarmcode
canbefoundinthe"ServoOnefunctional
SafetyErrorDescription".
Analarmoccuredatthe
safetycontroller.
l Pleasecheckthesafetyprogramandthe
wiringofthesafetysystem.
l Pleaseacknowledgethealarmatthesafety
master.Thesafetymasteracknowledgesall
slavealarmsandresetsthenetworkstatusto
"RUN".