11.6.44.3Error47-2(emergencycode6100h)
Cause: Error while requesting data from safety system
Suggested steps:
Acknowledge error, if the error occurs again, reset device
Anerroroccurredinthe
communicationtothesafety
system.
l Pleaseacknowledgetheerror.
l Iftheerroroccursagainpleaserestartthe
application(24Vreset).
Thisisprobablyasoftware
issue.
l Pleasetrytoswitchtoadifferentversionof
devicefirmware.
l Saveyourdatasetandresettheaxismoduleto
factorysetting.Seeiftheerrorpersists,orifit
comeswithactivatingacertainfeature.
11.6.44.4Error47-3(emergencycode6100h)
Cause: Download of safe PLC application file failed
Suggested steps:
Acknowledge error and try download again
Anerroroccuredattheup-
ordownloadofthesafety
programm.
l Pleasecheckthesecurityprogram.
l Pleasechecktheconnectionsettingsofyour
safetysysteminSafePLCS.
l Pleasereloadordownloadthesafetyprogram
again.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
441
11 Alarms & warnings
11.6.44.5Error47-4(emergencycode6100h)
Cause: Upload of safe PLC application file failed
Suggested steps:
Acknowledge error and try upload again
Anerroroccuredattheup-
ordownloadofthesafety
programm.
l Pleasecheckthesecurityprogram.
l Pleasechecktheconnectionsettingsofyour
safetysysteminSafePLCS.
l Pleasereloadordownloadthesafetyprogram
again.
11.6.44.6Error47-5(emergencycode6100h)
Cause: Safety firmware invalid (no firmware or CRC failure)
Suggested steps:
Update of safety firmware required, contact your service provider
Invalidsafetyfirmware. l Anupdateoftherequiredsafetyfirmwareis
necessary.
l Pleasereportthiserrortoyourservicepartner.