11.6.32Error33:Internaltimingerror
11.6.32.1Error33-0(emergencycode5300h)
Cause: ADCtask automatically interrupted
Suggested steps:
Please restart device.
Computationalloadintime-
criticaltaskofaxismoduleis
toohigh.
l Pleasereducecomputationalloadby
removingparametersfrommapping.
l De-activatefeaturesofcontrolsystemor
motioncontrol.
Thisisprobablyasoftware
issue.
l Pleasetrytoswitchtoadifferentversionof
devicefirmware.
l Saveyourdatasetandresettheaxismoduleto
factorysetting.Seeiftheerrorpersists,orifit
comeswithactivatingacertainfeature.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
418
11 Alarms & warnings
11.6.32.2Error33-1(emergencycode5300h)
Cause: Controltask exceededscantime
Suggested steps:
Please restart device.
Computationalloadintime-
criticaltaskofaxismoduleis
toohigh.
l Pleasereducecomputationalloadby
removingparametersfrommapping.
l De-activatefeaturesofcontrolsystemor
motioncontrol.
Thisisprobablyasoftware
issue.
l Pleasetrytoswitchtoadifferentversionof
devicefirmware.
l Saveyourdatasetandresettheaxismoduleto
factorysetting.Seeiftheerrorpersists,orifit
comeswithactivatingacertainfeature.